CONNECTOR- MC/MS Series
for core-insulated double and sandwich panels
MC/MS series fiber-composite connectors are designed for the construction of non-composite, load-bearing and cladding concrete sandwich panels. |
The connectors are corrosion and alkali resistant and, when combined with rigid insulation, provide an integral insulation system for concrete walls and a connection between two wythes, or layers, of concrete to transfer loads to the structural wythe. |
Permits & Certificates |
Permits for sandwich wall (SW) |
Z-21.8-1878 SW permit renewal 2016 |
Z-21.8-1878 SW incl. Twist-Anchor 2014 |
Z-21.8-1878 SW permit extension 2014 |
Writing about the update concerning expired permit Z-21.8-1878 |
Writing about permit Z-21.8-1878 und Z-21.8-1911 2018 |
Permits for double wall (DW) |
Z-21.8-1911 DW- permit renewal 2015 |
Permits for double wall (DW) and sandwich wall (SW) |
Z-21.8-1911 DW and SW permit extension 2018 |
Z-21.8-1911 DW and SW permit extension 2017 |
Certificates of compliance |
Certificate of compliance BWU03-0170-Z-21.8-1911-2020 |
Certificate of compliance BWU03-0012-Z-21.8-1878-2018 |
Property & Test | Concrete Strength | Single connector- MC Series | Single Connector- MS Series |
---|---|---|---|
With fascia wythe ≥ 2.5" (63 mm) | With fascia wythe <2.5" (63mm) | ||
Tensile strength of connector rod | N/A | 126,000 psi | 126,000 psi |
ASTMD3039/D3039M | (869 MPa) | (869 MPa) | |
Flexural strength of connector rod | N/A | 120,000 psi | 120,000 psi |
ASTM D790 | (827 Mpa) | (827 Mpa) |
Anchor Length | Wall Thickness | pcs./Carton | m²/Carton | pcs./Pallet | m²/Pallet | |
---|---|---|---|---|---|---|
288 | 300 | 500 | 144 | 11.000 | 3.456 | |
338 | 350 | 500 | 128 | 11.000 | 3.072 | |
388 | 400 | 500 | 96 | 11.000 | 2.304 | |
438 | 450 | 400 | 64 | 8.800 | 1.536 | |
488 | 500 | 400 | 8.800 |